Signature Edition MicroSilk® -AirMasseur® Touchpad

 

Operating Instructions

MicroSilk® On/Off Icon
To control the operation of the MicroSilk pump motor, press and release for each setting: ON or OFF. A 20 minute decreasing timer will be initiated when the pump motor starts. Press and hold the Pump icon to cycle through each pump setting. The Pump icon lights when the water is at operating level and the LCD displays “System Ready”. The LCD will display “Pump On”, or “Pump Off” when the key is pressed. It also toggles between Temperature and Timer at 5 second intervals. “Low Water” is displayed for 5 seconds if no water is detected. “Vacuum Error” is displayed if the MicroSilk suction is blocked.

Blower On/Off and Modes Icon
To control the operation of the blower, simply press and release to change the setting to Constant, Wave, Pulse or Off. A 20 minute decreasing timer will be initiated when the blower motor starts. Press and hold the Blower icon to cycle though blower modes. The Blower icon should remain lit as long as the bath is connected to a power supply. The LCD will display “Const Air” and blower speed, “Wave Air” and blower speed, or “Pulse Air” and blower speed, while the key is pressed. The time remaining on the purge cycle is displayed after the bath has drained. “Purge Stop” is displayed while the key is pressed during the purge cycle. This action will terminate the purge cycle. The mode settings will be remembered on the next startup.

Blower Speeds Icon
Hold the key in Constant mode to go from High to Low then release and hold again to go from Low to High. Hold the key in Wave and Pulse mode to go from High to Medium and Medium to High. The system remembers the last speed setting on the next startup. The Blower Speeds icon will light up when the blower is running. The LED displays the blower speed from “10” (Low) or “55”(Med) to “99” (High) while the key is pressed. You can reduce the auto purge idle time from 20 minutes to 10 minutes, by pressing and holding the key for more than 5-seconds during the purge idle period.

LED Light Icon
Hold the key for less than two (2) seconds to turn the lights Off or On. Hold the key for more than two (2) seconds to change modes. The Light icon should remain lit as long as the bath is connected to a power supply. This function has a two-hour timer and remembers the last mode. The LCD displays“Light On” or “Light Off while the key is pressed for less than two (2) seconds, “Light Cycle” is displayed if pressed for more than two (2) seconds.

Customized Settings
The 12 character LCD display can be customized by pressing the Blower and Blower Speeds icon simultaneously for five (5) seconds, while the system is off. Note : The Blower Speeds icon will not be illuminated during this process. Use the above figure to locate the icons and LCD display. A menu will be displayed to choose the following: Purge 24, (starts the blower every 24 hours for two (2) minutes at the time the purge was set), Product Test Diagnostics, Temperature (F or C) and Language (English or Spanish).

Menu Instructions
Use the top Diagnostic Function icon to scroll through the different menu items. Use the bottom Diagnostic Function icon to change an option. For example, press and release the top icon to change from Product Test to the Temperature option. Press and release the bottom icon to change the temperature display from F (Fahrenheit) to C (Celsius).

Product Test Diagnostics
After selecting the Product Test option from the menu, the unit will perform a series of tests to confirm correct installation of components. The test will begin by displaying the configuration number, followed by the software revision number. Next, the auxiliary control box will be tested to ensure proper IR communication. The display will then test the Temperature and Low Water level sensor (ITW-209). Next, each of the six (6) icon buttons will begin to light. Press the illuminated button to proceed to the next icon. After the icon test, the blower will start for two (2) seconds on the High setting. Lastly, the LED Light unit will be tested. If you receive an error on any of the tests, confirm proper installation of component to the correct control box. (See the CONTROL BOX CONNECTIONS section).

Remote Control
The Signature Edition control system includes a waterproof floating Universal Remote Control. It controls all bath functions plus a TV, DVD, CD, etc. which can be heard through the Sound Immersion Transducers (optional).
 