SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTION
Insufficient water
  1. Supply pressure inadequate
  2. Filters on thermostat cartridge dirty
  3. Screen washer dirty
  1. Check water pressure (If a pump has been installed, check to see if the pump is working).
  2. Clean thermostat filters
  3. Clean screen washer between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed
  1. Check valves dirty or leaking
  1. Clean check valves, replace if necessary
Output temperature does not correspond with temperature set
  1. Handle not justified
  1. Justify handle
 
  1. Hot water temperature too low
  1. Reset high temperature limit stop
Temperature regulation not possible
  1. Temperature regulator dirty or calcified
  2. Panel is cross-connected
  1. Clean temperature regulator, replace if necessary
  2. Connect supply hoses to correct supplies
Safety stop override button not operating
  1. Spring defective
  2. Button calcified
  1. Clean spring and/or button, replace if necessary
Diverter control stiff
  1. Diverter cartridge defective or dirty
  1. Replace cartridge
 